Issue
User application does not check if the form is dirty and does not display dirty popup on click of Cancel. This occurs after updating Pega Platform 8.7.6 to Pega Infinity 24.2.3.
Symptoms and Impact
Dirty pop up does not display
Steps to reproduce
- Create a text input / Input control with Post Value or Refresh action on the user application.
- Enter data into the Input control.
- Click Cancel.
Root Cause
pzpega_ui_doc_dirtyhandling JS file contains incorrect code.
Solution
- Update to Pega Platform 24.2.3.
- Apply HFix-D398.
This issue is addressed in Pega Platform 24.2.4, Pega Infinity’ 25, and Pega Infinity’ 26